logo
Send Message
English

YW DKE TRADING COMPANY

Home ProductsPulse Valve Diaphragm

GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve

GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve

  • GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve
  • GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve
  • GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve
  • GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve
GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve
Product Details:
Place of Origin: China
Brand Name: GOYEN
Certification: CE
Model Number: CA102MM
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Plastic bag, Box, Carton, Pallet
Delivery Time: 1-7Work Days After Payment
Payment Terms: T/T, Western Union,Paypal
Supply Ability: 5000 pieces/1Month
Contact Now
Detailed Product Description
Model No: GOYEN Voltages: DC24V, AC24V, AC110V, AC220V
Port Size: 3 1/2'' Temperature Range: -5 To +55℃
Diaphragm Number: 2 Pressure Range: 0.3 To 0.8Mpa
Thread Type: NPT, G Diaphragm Material: Nitrile
Operating Pressure: 3~8bar Series: Manifold Mount (MM)
Highlight:

Replacement GOYEN Dust Collector Valve

,

CA102MM GOYEN Dust Collector Valve

,

3 1/2'' Dust Collector Valve

Product Attributes

Model No.: CA102MM

Brand: GOYEN

Number Of Diaphragm: 2

Name: CA102MM Goyen Type Pulse Jet Valve

Remote Or Integral: Integral Piloted

Series: Manifold Mount (MM)

Pipe Size: 3 1/2 Inch

Diaphragm Material: Nitrile

Body Material: ADC Aluminum

Operating Pressure: 3~8bar

Operating Temperature: -5~+55℃

Available Voltages: 24VAC, 110V/120VAC 200/240VAC, 12VDC, 24VDC

GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve

What is a Dust Collector Pulse Jet Valve?
Diaphragm pulse valves are the most important components of a baghouse pulse jet cleaning system.

On a pulse jet baghouse pulse valves (also called diaphragm valves) control the release of air pulses during the cleaning cycle. When the baghouse control board or timer board initiates a cleaning cycle it sends an electrical signal to the solenoids, when then activate the pulse valve. Inside the pulse valve, a rubber diaphragm opens and closes to release the compressed air stored in the air header tank. The air then passes through the valve into the blow pipes above the filters and then is directed down into the filters to clean them.

 

Technical data of MM Series Full Immersion Manifold Flat Mount Valves:

 

Model No
CA25MM
CA40MM
CA50MM
CA62MM
CA76MM
CA102MM
Nominal Size
25
40
50
62
76
102
Port Size
mm
25
40
50
62
76
102
inch
1''
1 1/2''
2''
2 1/2''
3''
3 1/2''
4''
Pressure Range
0.3 to 0.8MPa
Temp. Range
Nitrile seals
-40 to 82℃
seals
-29 to 232℃

 

 

Overall dimension of CA102MM Goyen Replacement Dust Collector Valve:

CA102MM Goyen Replacement Dust Collector Valve

 

Details display of CA102MM Goyen Type Dust Collector Pulse Valve:

GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve 1

 

Spare Parts of Full Immerse Manifold Mounted Pulse Jet Valve:

CA89MM pulse double NBR/ diaphragm valve structure and material chart

 

Part Name Material
Solenoid coil Enamelled wire
Armature assembly SS304, 430FR
Small common cap ADC aluminum (die cast)
Diaphragm NBR (Nitrile, buna-n)
Top end cap ADC aluminum (die cast)
Big spring SS304
Screws SS302
Seal NBR,
Main body ADC aluminum (die cast)
 

 

Pulse jet valves must do the following safety inspection before it is officially delivered:

1. Insulation resistance test:
(1) Measure the insulation resistance of the solenoid coil to the outer casing under the specified environmental conditions using a 500V meter with a range of 0MΩ to 500MΩ and an accuracy of 1 meter.
(2) Put the valve in the temperature regulation and humidity control box, and set the temperature to 35 degrees, and the relative humidity is 85%, apply a 50Hz, 250V sinusoidal AC voltage between the electromagnetic coil and the valve body for 1min. Check for breakdown.

2. Anti-vibration test: the valve is fixed on the vibration test bench, after the vibration frequency is 20Hz, the full amplitude is 2mm, after 30min vibration, check whether the fasteners of each part of the valve are loose, whether the work is normal.

3. Diaphragm service life test: Connect the clean air of nominal pressure to the air inlet of the electromagnetic pulse valve, and input the nominal voltage value of 0.1s width and interval of 3s on the Solenoid Valve, and record the number of continuous or cumulative work of the valve.

GOYEN 3 1/2'' CA102MM Replacement Dust Collector Valve 3 

Contact Details
YW DKE TRADING COMPANY

Contact Person: Aria

Tel: +8617371234005

Send your inquiry directly to us
Other Products